Insulation Class of Fastening Systems and Compatibility with Electrified Railways
What are the core technical indicators of national standard Class III insulated fastening systems?
The national standard Class III insulated fastening system must first meet the insulation resistance requirement. At 20℃ and 60% humidity, the insulation resistance must be ≥10^9Ω to ensure current isolation effect. It must pass the power frequency withstand voltage test and remain non-breakdown and non-flashover for 1 minute under 5kV voltage, adapting to the power supply environment of high-voltage electrified railways. Insulating components in the system, such as insulating gauge blocks and insulating gaskets, must be made of high-temperature resistant epoxy glass fiber material, which can maintain stable insulation performance in the temperature range of -40℃ to 120℃. The anti-aging performance of insulating components must meet the standard. After 3000 hours of ultraviolet aging test, the insulation resistance attenuation is ≤10%, meeting the needs of long-term outdoor use. In addition, the overall insulation structure of the system must have a water-proof design, and there are no water accumulation grooves on the insulation interface to avoid insulation performance degradation caused by humid environments.

What are the differences between foreign standard UIC insulated fastening systems and national standard insulated systems?
The insulation grade classification of foreign standard UIC insulated fastening systems is more detailed, divided into UIC A, B, and C grades, while the national standard only has three-level classification. The UIC standard can more accurately adapt to lines of different voltage levels. The insulating components of the UIC system are made of polyimide material, whose high-temperature resistance can reach 150℃, far exceeding the 120℃ of the national standard epoxy material, adapting to high-power electrified lines. The insulation test standard of the UIC system is more stringent, requiring to pass the 10kV impulse withstand voltage test, while the national standard Class III only has 5kV power frequency withstand voltage, with higher safety requirements. In structural design, the insulating components of the UIC system are modularly designed and can be quickly replaced, while the national standard system is mostly an integrated structure with insufficient maintenance flexibility. In addition, the insulation life of the UIC system can reach 30 years, longer than the 20-year life of the national standard system, and the life-cycle cost is lower.

How do insulated fastening systems prevent stray current from corroding tracks?
Insulated fastening systems first isolate the rail from the track bed and sleepers through insulating components, cutting off the leakage channel of stray current and avoiding current flowing into the track bed to corrode steel bars. The insulation interface of the system has excellent sealing performance, which can prevent rainwater and snowmelt from penetrating to form conductive paths and maintain stable insulation performance. The insulation resistance of the insulated fastening system is high enough to hinder the conduction of stray current, making the current flow along the preset return channel without leakage. Insulating components such as insulating gauge blocks in the system have electrochemical corrosion resistance and will not produce galvanic corrosion due to current leakage, and their service life is not affected. In addition, the insulated fastening system can cooperate with the stray current monitoring device to monitor the current leakage in real time, and can give an early warning in time once insulation failure occurs, preventing track corrosion from both protection and monitoring aspects.

Why do urban rail express lines need to use high-grade insulated fastening systems?
Urban rail express lines have high train operation density and high power supply system load, and the probability of stray current generation is much higher than that of ordinary railways. Therefore, a high-grade insulation system is required to block current leakage. Most urban rail express lines are underground lines with humid environments and poor ventilation conditions. Insulating components are prone to moisture and aging. High-grade systems have stronger moisture and aging resistance and can maintain long-term insulation effects. The signal system of urban rail express lines is extremely sensitive to current interference. High-grade insulation systems can avoid stray current interfering with signal transmission and prevent train failures such as signal inaccuracy and parking. The maintenance space of urban rail lines is narrow, and the service life of high-grade insulation systems is longer, which can reduce the workload of frequently replacing insulating components and lower maintenance difficulty. At the same time, urban rail express lines have dense passenger flow and extremely high safety requirements. High-grade insulation systems can minimize safety accidents caused by electric leakage.
What are the key points of on-site maintenance for insulated fastening systems?
The on-site maintenance of insulated fastening systems first needs to regularly test the insulation resistance. An insulation resistance meter is used for random inspection every quarter to ensure that the insulation resistance is not less than 80% of the design value. If it is lower than the standard, the components must be replaced in time. The appearance state of insulating components needs to be checked to find out whether there are defects such as cracks, damage, and carbonization, which will lead to a sudden drop in insulation performance. During maintenance, dust and oil stains on the surface of insulating components must be cleaned to prevent pollutants from forming a conductive film and affecting the insulation effect. For the sealed structure, the aging of the sealing rubber strip needs to be checked, and the failed rubber strip should be replaced in time to ensure the sealing performance of the insulation interface. In addition, the temperature of insulating components should be monitored. If abnormal temperature rise occurs, it is necessary to check whether there is insulation aging or current leakage to prevent high temperature from further damaging the insulation system and ensure the safe operation of electrified lines.