European Standard for Fastening Systems (DIN EN 17319:2020) Requirements

Nov 14, 2025 Leave a message

European Standard for Fastening Systems (DIN EN 17319:2020) Requirements

 

What performance classes does the DIN EN 17319:2020 standard divide the fastening system into?

According to the maximum design axle load and minimum curve radius, the standard divides the fastening system into three classes: A+, A, and B. Class A+ has a maximum design axle load of 130kN and a minimum curve radius of 18m, suitable for small-radius curve lines in urban central areas. Class A has a maximum design axle load of 130kN and a minimum curve radius of 40m, suitable for general urban lines. Class B has a maximum design axle load of 180kN and a minimum curve radius of 80m, suitable for heavy-haul lines and industrial railways. The performance requirements of different classes are clearly different, and selection must be based on line working conditions.

 

kpo-rail-fastening-system-2

 

What requirements does the standard have for the longitudinal resistance of the fastening system?

The average longitudinal resistance of the mechanical embedded track fastening system must be at least 7kN, and the test shall be carried out in accordance with EN 13146-1. For the bonded fastening system, the longitudinal stiffness kL needs to be measured within the relative displacement range of 0mm to Drmm, and the minimum longitudinal force is also required to be 7kN. The default value of Dr is 7mm, which can be negotiated by the supplier and the customer in special cases. Longitudinal resistance is a key indicator to ensure the longitudinal stability of the rail, which can prevent excessive displacement of the rail during train operation. The standard ensures the comparability of the performance of different products by clarifying test methods and indicators.

 

Rail Fastener

 

What are the parameter requirements for the vertical stiffness test of the fastening system?

The vertical stiffness test requires the load to pass through the center line of the rail web, and the test load value varies according to the fastening class. For classes A and A+, FSA1 and FLFA1 are 1kN, and FSAmax and FLFAmax are 32kN. For class B, FSA1 and FLFA1 are 1kN, and FSAmax and FLFAmax are 43kN. The measured stiffness kSA and kLFA shall be expressed in units per meter length (MN/m per m). Ballasted track and monolithic track bed adopt different load parameters for stiffness testing to ensure that the test results are consistent with the actual application scenarios. These parameter requirements can fully reflect the vertical bearing capacity of the fastening system.

 

skl-rail-fastening-system

 

What performance requirements must the fastening system meet after the repeated load fatigue test?

The fatigue test is carried out in accordance with EN 13146-4 without measuring the clamping force. After the test, the change of longitudinal resistance or stiffness shall not exceed 20% to ensure that the longitudinal stability is not affected. The change of vertical static stiffness shall not exceed 25% to ensure stable cushioning and supporting performance. No visible cracks shall appear in any components of the fastening system, and the waterproof sealing components shall not be damaged or deformed. The test simulates the mechanical environment in actual operation to ensure that the fastening system does not fail during long-term use and guarantees track safety.

 

What special requirements must the fastening system meet in corrosive environments?

The performance in corrosive environments shall be determined according to specific project requirements, and severe environmental exposure tests shall be carried out in accordance with EN 13146-6. After the test, the fastening system must be detachable and reinstallable with specified hand tools to ensure maintenance convenience. No component shall fail, and the original connection strength and sealing performance must be maintained. Corrosion resistance shall be a priority in material selection, and special surface treatment shall be adopted if necessary. It is also necessary to ensure that the electrical insulation performance is not affected by corrosion to avoid affecting the track circuit system.