Corrosion Protection Classification and Life Cycle Protection Technology for Rail Components

 

What are the core judgment indicators for the anti-corrosion protection classification of track components?

The core judgment indicators for the anti-corrosion protection classification of track components are set around the corrosion factors of the service environment, mainly including four indicators: environmental relative humidity, salt spray content, sulfur dioxide concentration and temperature variation range, and a comprehensive judgment is made in combination with the environment type. Relative humidity is the basic indicator: C1 mild corrosion environment has a relative humidity ≤60%, mainly indoor station yards and dry inland areas; C2 moderate corrosion has a humidity of 60%-80%, ordinary open lines and non-coastal plain areas; C3 severe corrosion has a humidity ≥80% and a salt spray content of 0.05-0.2mg/m³, within 30km of the coast and lightly chemical-polluted areas; C4 extreme corrosion has a humidity ≥90%, a salt spray content ≥0.2mg/m³ or a sulfur dioxide concentration ≥0.15mg/m³, within 10km of the coast, heavily chemical-polluted, high-humidity and rainy areas. The temperature variation range is an auxiliary indicator. In areas where the annual temperature variation range is ≥40℃, the corrosion rate will increase by 15%-20%, and the protection grade needs to be appropriately increased on the basis of the original classification. In addition, factors such as the presence of ponding and dust pollution will also affect the classification, and components in ponding areas need additional anti-immersion protection.

 

kpo-rail-fastening-system-2

 

What are the core protection processes of track metal components under different anti-corrosion grades?

The core protection processes of track metal components under different anti-corrosion grades are upgraded gradiently from basic coating to composite protection according to the corrosion degree, ensuring that the protection effect is precisely matched with the corrosion grade. For C1 mild corrosion grade, the core adopts electro-galvanizing + passivation treatment process, with an electro-galvanizing layer thickness of 8-10μm. Passivation treatment improves the adhesion of the zinc layer, which is mainly applicable to bolts, pressure plates and other components in indoor station yards to meet basic anti-corrosion needs. For C2 moderate corrosion grade, the hot-dip galvanizing process is adopted, with a zinc layer thickness of 60-80μm. The compactness and wear resistance of the zinc layer are better than electro-galvanizing, applicable to fish plates, rail spikes and other components in ordinary open lines, which can resist daily wind and rain corrosion. For C3 severe corrosion grade, the hot-dip galvanizing + closed coating composite process is adopted, and an epoxy closed coating is sprayed on the basis of hot-dip galvanizing, with a total protective layer thickness of 100-120μm, applicable to rail joints and fastening bolts in coastal salt spray areas, with both salt spray and wear resistance. For C4 extreme corrosion grade, the high-end composite process of Dacromet coating + fluorocarbon topcoat is adopted. The Dacromet coating has salt spray resistance of more than 1000h, and the fluorocarbon topcoat has excellent weather resistance, with a total thickness of 150-200μm, applicable to all metal components in coastal heavy salt spray and chemical pollution areas, achieving long-term anti-corrosion.

 

e-clip-fastening-systen-1

 

How is the anti-corrosion protection of rails different from that of other metal components, and what are the core protection focuses?

The core difference between the anti-corrosion protection of rails and metal components such as bolts and fish plates stems from the working characteristic that rails need to bear repeated wheel-rail rolling and friction, and cannot be protected by thick coatings. It is necessary to follow the principle of "light protection in wear areas, heavy protection in non-wear areas". The core protection focuses are four parts: the non-wear area of the rail head, rail web, rail base and rail joints. Compared with other components, any thick coating on the wear area of the rail head will fall off quickly due to continuous wheel-rail friction, and will affect the smoothness of wheel-rail contact. Therefore, only thin anti-rust oil is used for light protection, focusing on rust prevention rather than anti-corrosion; while other components have no wear requirements, thick coatings can be used to achieve long-term anti-corrosion. The core protection focuses of the rail are first the non-wear area of the rail head, which is sprayed with special rail anti-rust paint with a coating thickness of 30-40μm to prevent corrosion by rain and dew; second the rail web and rail base, which are treated with hot-dip galvanizing or epoxy coating with a thickness of 80-100μm to resist side corrosion; third the rail joints, where the joint gaps are prone to water accumulation and rusting, filled with anti-corrosion sealant, and the periphery of bolt holes is edge-sealed; finally the rail ends, treated with chamfering + anti-corrosion coating to prevent the expansion of end corrosion. In addition, the welded joints of rails are weak points of anti-corrosion, which need to be protected focusly with special welding anti-rust paint.

 

Rail Fastener

 

What are the core requirements for anti-corrosion protection measures in the transportation and storage stage of track components?

The anti-corrosion protection of track components in the transportation and storage stage is core to prevent bump damage during transportation and moisture corrosion during storage. It is necessary to follow the three core requirements of anti-damage, anti-moisture and anti-contact corrosion to ensure the integrity of the protective layer and the components themselves. In terms of anti-damage, metal components must be stacked in layers with foam gaskets and plastic film wrapping during transportation to avoid mutual collision leading to protective layer falling off. Rails must be transported by special trolleys, and anti-collision caps are installed at the ends to prevent deformation of the rail head and base and coating scratches. The damaged parts must be touched up in time. In terms of anti-moisture, components must be stored in a dry and ventilated indoor warehouse with a relative humidity controlled below 60%. For temporary open storage, they must be fully covered with rainproof cloth, with moisture-proof pads laid at the bottom and raised ≥30cm from the ground to prevent corrosion by ground moisture return. Regular inspections are carried out at the same time, and ventilation and dehumidification are carried out in time if condensation is found. In terms of anti-contact corrosion, components of different materials are prohibited from being mixed and stored, such as carbon steel bolts and stainless steel pressure plates must be stored separately to avoid electrochemical contact corrosion; the contact parts between components and the ground and supports must be isolated with insulating pads to prevent contact corrosion. In addition, components with a storage period of more than 6 months need to be re-sprayed with anti-rust oil to ensure that the anti-corrosion effect does not attenuate.

 

How to realize the dynamic management and control of the whole life cycle of anti-corrosion protection of track components in the operation and maintenance stage?

The dynamic management and control of anti-corrosion protection of track components in the operation and maintenance stage is core to the principle of regular inspection, classified maintenance and timely repair. According to the corrosion degree and service life of the components, differentiated maintenance measures are formulated to realize the whole life cycle management and control from laying to scrapping. First, regular inspection: set the inspection cycle according to the anti-corrosion grade, inspect C1/C2 grades every 1-2 years, and C3/C4 grades every 6-12 months. Adopt visual inspection + coating thickness gauge detection, focus on checking problems such as protective layer falling off, corrosion and bulging, and record the corrosion parts and degree. Second, classified maintenance: divide the maintenance grades according to the inspection results. Mild corrosion (protective layer falling off <5%) is treated with touch-up protective paint; moderate corrosion (falling off 5%-20%) is treated with grinding and derusting + re-spraying coating; severe corrosion (falling off >20% or pitting) is treated with component replacement to avoid the expansion of corrosion affecting structural strength. Finally, timely repair: after corrosion problems are found in the inspection, the repair must be completed within 7 days. The repair process is consistent with the original protection process, and the coating thickness and material are not lower than the original design standards. After repair, records are made and included in the whole life cycle file of the components. In addition, for key components of heavy-haul and high-speed lines, online monitoring technology is adopted to monitor the corrosion state in real time, realizing the upgrade from "regular maintenance" to "predictive maintenance" to ensure that the anti-corrosion protection of components always meets the standard.